9-26
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.16 INH-MSG-ALL
condtype Condition type of the alarm or event that is to be
inhibited (maps to cerent15216EdfaLogEventID). ALL
maps to all types. A null maps to none of the types, i.e.,
with a null, all existing condtype allowances are kept
unchanged. Possible condtype and corresponding
conddescr (in quotes) are:
LOS “Loss of Signal” (input power) alarm
(cerent15216EdfaAlarmLpin).
GAIN “Gain Out of Range” alarm
(cerent15216EdfaAlarmGain).
LPOUT “Loss of Output Power” alarm
(cerent15216EdfaAlarmLpout).
CTMP “Case Temperature Out of Range” alarm
(cerent15216EdfaAlarmCtmp).
DBBACKUP “Database Backup In Progress” alarm
(cerent15216EdfaOpDbBackup).
DBRESTORE Database Restore In Progress” alarm
(cerent15216EdfaOpDbRestore).
LCRNT1 “Excessive Pump1 Current” alarm
(cerent15216EdfaAlarmLcrnt1).
Table 9-22 INH-MSG-ALL Syntax Description (continued)