Resumo do Conteúdo

Página 1 - Blade Server

CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV C.11 SEPTEMBER 10, 2014 WWW.CISCO.COMSpec SheetCisco UCS B200 M3Blade S

Página 2

Cisco UCS B200 M3 Blade Server10CONFIGURING the SERVERSupported Configurations(1) One-CPU Configuration Choose one CPU from any one of the rows of Ta

Página 3 - OVERVIEW

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER11— The connectivity options are:• VIC 1340 or 1240 installed in VIC 1340/1240 slot and no adapter

Página 4 - DETAILED VIEWS

Cisco UCS B200 M3 Blade Server12CONFIGURING the SERVERSTEP 3 CHOOSE MEMORYThe standard memory features are: DIMMs— Clock speed: 1866, 1600, or 1333 M

Página 5

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER13Choose DIMMs and Memory MirroringSelect the memory configuration and whether or not you want the

Página 6

Cisco UCS B200 M3 Blade Server14CONFIGURING the SERVERSupported Configurations(1) B200 M3 configured with 1 CPU without memory mirroring Select from

Página 7

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER15(3) B200 M3 configured with 2 CPUs without memory mirroring: Select from 1 to 12 DIMMs per CPU

Página 8 - STEP 1 VERIFY SERVER SKU

Cisco UCS B200 M3 Blade Server16CONFIGURING the SERVERCaveats System speed is dependent on how many DIMMs are populated per channel. See Table 7 for

Página 9 - STEP 2 CHOOSE CPU(S)

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER17— DIMM choice— DIMM population (how many DIMMs per channel are populated)— BIOS setting. For the

Página 10 - Notes

Cisco UCS B200 M3 Blade Server18CONFIGURING the SERVERSTEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES (OPTIONAL)The UCS B200 M3 can be ordered wi

Página 11

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER19Supported Configurations(1) 1-Drive System Select one of the drives listed in Table 8. (1) 2-Dr

Página 12 - STEP 3 CHOOSE MEMORY

Cisco UCS B200 M3 Blade Server2OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3DETAILED VIEWS

Página 13

Cisco UCS B200 M3 Blade Server20CONFIGURING the SERVERSTEP 5 CHOOSE ADAPTERSThe adapter offerings are: Cisco Virtual Interface Cards (VICs)Cisco deve

Página 14

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER21Supported Configurations(1) B200 M3 configured with 1 CPUFor a B200 M3 configured with 1 CPU, th

Página 15

Cisco UCS B200 M3 Blade Server22CONFIGURING the SERVER(2) B200 M3 configured with 2 CPUsFor a B200 M3 configured with 2 CPUs, the supported configurat

Página 16

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER23Also see NEBS Compliance on page 49 for more information.To help ensure that your operating syst

Página 17 - CONFIGURING the SERVER

Cisco UCS B200 M3 Blade Server24CONFIGURING the SERVERSTEP 6 ORDER A TRUSTED PLATFORM MODULETrusted Platform Module (TPM) is a computer chip (microcon

Página 18

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER25STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDSDual SDHC flash card sockets are provided

Página 19

Cisco UCS B200 M3 Blade Server26CONFIGURING the SERVERSTEP 8 ORDER OPTIONAL INTERNAL USB 2.0 DRIVEYou may order one optional internal USB 2.0 drive. T

Página 20 - STEP 5 CHOOSE ADAPTERS

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER27STEP 9 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARESeveral operating systems and value-added

Página 21

Cisco UCS B200 M3 Blade Server28CONFIGURING the SERVERRed Hat Enterprise LinuxRHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs RequiredRHEL-2S-1G-3A RHEL/

Página 22

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER29VMware 5VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support RqdVMW-VS5-STD

Página 23

Cisco UCS B200 M3 Blade ServerOVERVIEW3OVERVIEWDelivering performance, versatility and density without compromise, the Cisco UCS B200 M3 Blade Server

Página 24

Cisco UCS B200 M3 Blade Server30CONFIGURING the SERVERSTEP 10 CHOOSE OPERATING SYSTEM MEDIA KITChoose the optional operating system media listed in Ta

Página 25

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER31STEP 11 CHOOSE SERVICE and SUPPORT LEVELA variety of service options are available, as described

Página 26

Cisco UCS B200 M3 Blade Server32CONFIGURING the SERVERUnified Computing Warranty Plus ServiceFor faster parts replacement than is provided with the st

Página 27

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER33Partner Support Service for UCS provides hardware and software support, including triage support

Página 28

Cisco UCS B200 M3 Blade Server34CONFIGURING the SERVERYou can choose a service listed in Table 21.Unified Computing Drive Retention ServiceWith the Ci

Página 29

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER35For more service and support information, see the following URL:http://www.cisco.com/en/US/servi

Página 30

Cisco UCS B200 M3 Blade Server36CONFIGURING the SERVERORDER OPTIONAL KVM LOCAL I/O CABLE*The KVM local I/O cable ships with every UCS 5100 Series blad

Página 31

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL37SUPPLEMENTAL MATERIALSystem BoardA top view of the UCS B200 M3 system board is shown in Figure 5.

Página 32

Cisco UCS B200 M3 Blade Server38SUPPLEMENTAL MATERIALCPUs and DIMMsPhysical LayoutMemory is organized as shown in Figure 6.Figure 6 UCS B200 M3 Memo

Página 33

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL39— Bank 1 - E1, F1, G1, and H1 (black DIMM slots)— Bank 2 - E2, F2, G2, and H2 (white DIMM slots)T

Página 34

Cisco UCS B200 M3 Blade Server4DETAILED VIEWSDETAILED VIEWSBlade Server Front ViewFigure 2 is a detailed front view of the Cisco UCS B200 M3 Blade Ser

Página 35

Cisco UCS B200 M3 Blade Server40SUPPLEMENTAL MATERIALDIMM Population Rules When considering the memory configuration of your server, you should take i

Página 36

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL41DIMM Population OrderPopulate the DIMMs for a CPU according to Table 25.Table 25 DIMM Populatio

Página 37 - SUPPLEMENTAL MATERIAL

Cisco UCS B200 M3 Blade Server42SUPPLEMENTAL MATERIALRecommended Memory ConfigurationThis section explains the recommended DIMM population order rules

Página 38 - CPUs and DIMMs

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL43192 GB4x8 GB 4x8 GB 4x8 GB 4x8 GB 4x8 GB 4x8 GB10663244x16 GB 2x16 GB — 4x16 GB 2x16 GB — 1866 12

Página 39

Cisco UCS B200 M3 Blade Server44SUPPLEMENTAL MATERIAL96 GB4x4 GB 4x4 GB 4x4 GB 4x4 GB 4x4 GB 4x4 GB 1066 244x8 GB 2x8 GB — 4x8 GB 2x8 GB — 1600 123x16

Página 40 - DIMM Population Rules

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL45Additional DIMM PopulationsThe list in Table 28 is not a complete list of all supported DIMM popu

Página 41 - DIMM Population Order

Cisco UCS B200 M3 Blade Server46SUPPLEMENTAL MATERIALUpgrade and Servicing-Related PartsThis section lists the upgrade and servicing-related parts you

Página 42

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL47Adding an Additional CPU (with CPU heat sink)All Cisco UCS two CPU socket-capable servers can be

Página 43

Cisco UCS B200 M3 Blade Server48SUPPLEMENTAL MATERIALAir Baffle Replacement KitAir baffles are designed to direct airflow through the server to mainta

Página 44

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL49NEBS ComplianceWhen configured with the specific set of components shown in Table 30, the UCS B20

Página 45 - Additional DIMM Populations

Cisco UCS B200 M3 Blade ServerBASE SERVER STANDARD CAPABILITIES and FEATURES5BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 lists the capabilit

Página 46

Cisco UCS B200 M3 Blade Server50SUPPLEMENTAL MATERIALNetwork ConnectivityThis section explains how the UCS B200 M3 server connects to Fabric Interconn

Página 47 - Motherboard Lithium Battery

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL51The network adapter options are: Cisco VIC 1340 or adapter. This adapter plugs into the VIC 1340

Página 48 - CPU Heat Sink Cleaning Kit

Cisco UCS B200 M3 Blade Server52SUPPLEMENTAL MATERIALFigure 9 VIC 1340/1240 Port ConnectivityThe number of ports available at the mezzanine adapter

Página 49 - NEBS Compliance

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL53 Emulex or QLogic I/O adapters—Emulex M73KR-E— QLogic M73KR-Q Cisco Storage Accelerator adapter

Página 50 - Network Connectivity

Cisco UCS B200 M3 Blade Server54SUPPLEMENTAL MATERIALFigure 10 Option 1 - VIC 1340/1240 to UCS 2208XP Fabric Extender (no mezzanine adapter)

Página 51 - VIC 1340/1240 Adapter

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL55In Figure 11, two ports from the VIC 1340/1240 are channeled to 2208XP Fabric Extender A and two

Página 52 - Mezzanine Adapters

Cisco UCS B200 M3 Blade Server56SUPPLEMENTAL MATERIALFigure 12 Option 1 - VIC 1340/1240 to UCS 2204XP Fabric Extender (no mezzanine adapter)In Figur

Página 53 - B200 M3 Configured with 1 CPU

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL57Connectivity using the Cisco UCS 2104XP Fabric ExtenderThe option shown in Figure 14 demonstrates

Página 54

Cisco UCS B200 M3 Blade Server58SUPPLEMENTAL MATERIALB200 M3 Configured with 2 CPUsConnectivity using the Cisco UCS 2208XP Fabric ExtenderThe Cisco UC

Página 55 - ■ VIC 1340/1240 to 2204XP

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL59In Figure 16, two ports from the VIC 1340/1240 are channeled to 2208XP Fabric Extender A and two

Página 56

Cisco UCS B200 M3 Blade Server6BASE SERVER STANDARD CAPABILITIES and FEATURESVideo The Cisco Integrated Management Controller (CIMC) provides video:

Página 57 - Fabric Extender

Cisco UCS B200 M3 Blade Server60SUPPLEMENTAL MATERIALIn Figure 18, two ports from the VIC 1340/1240are channeled to 2208XP Fabric Extender A and two a

Página 58

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL61Connectivity using the Cisco UCS 2204XP Fabric ExtenderThe Cisco UCS 2204XP is a second-generatio

Página 59

Cisco UCS B200 M3 Blade Server62SUPPLEMENTAL MATERIALIn Figure 21, one port from the VIC 1340/1240 is channeled to 2204XP Fabric Extender A and one is

Página 60

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL63In Figure 23, one port from the VIC 1340/1240 is channeled to 2204XP Fabric Extender A and one is

Página 61

Cisco UCS B200 M3 Blade Server64SUPPLEMENTAL MATERIALConnectivity using the Cisco UCS 2104XP Fabric ExtenderThe options shown in Figure 25 and Figure

Página 62

Cisco UCS B200 M3 Blade ServerSUPPLEMENTAL MATERIAL65Figure 26 Option 2 - VIC 1340/1240 to UCS 2104XP Fabric Extender (Cisco Storage Accelerator ins

Página 63

Cisco UCS B200 M3 Blade Server66TECHNICAL SPECIFICATIONSTECHNICAL SPECIFICATIONSDimensions and WeightPower SpecificationsFor configuration-specific po

Página 64

Cisco UCS B200 M3 Blade ServerTECHNICAL SPECIFICATIONS67

Página 65

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER7CONFIGURING the SERVERFollow these steps to configure the Cisco UCS B200 M3 Blade Server: STEP 1

Página 66 - TECHNICAL SPECIFICATIONS

Cisco UCS B200 M3 Blade Server8CONFIGURING the SERVERSTEP 1 VERIFY SERVER SKUVerify the product ID (PID) of the server as shown in Table 2.The base Ci

Página 67

Cisco UCS B200 M3 Blade ServerCONFIGURING the SERVER9STEP 2 CHOOSE CPU(S)The standard CPU features are: Intel Xeon E5-2600 v2 and E5-2600 series proc