CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.1 NOVEMBER 2, 2012 WWW.CISCO.COMCisco UCS C22 M3High-Density Rack-Mou
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server10CONFIGURING the SERVERSTEP 2 SELECT CPU(s)The standard CPU features are: Intel Xeon E5-2400 seri
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER11 For optimal performance, select DIMMs with the highest clock speed for a
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server12CONFIGURING the SERVERSTEP 3 SELECT MEMORYThe standard memory features are: DIMMs— Clock speed:
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER13Select DIMMsSelect the memory configuration. The available memory DIMMs are
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server14CONFIGURING the SERVER Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on p
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER15STEP 4 SELECT RAID CONFIGURATIONThe RAID controller choices are: Software
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server16CONFIGURING the SERVERTable 6 Available Hardware RAID Options Product ID (PID) PID DescriptionR
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER17Approved ConfigurationsSelect a software RAID option from Table 5 on page 1
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server18CONFIGURING the SERVER— Note that only a single Cisco 1225 Virtual Interface Card (VIC) card is s
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER19STEP 5 SELECT HARD DISK DRIVES (HDDs)The standard disk drive features are:
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server2CONTENTS OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server20CONFIGURING the SERVERApproved Configurations(1) Software RAID (LSI MegaSR) Select up to eight S
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER21STEP 6 SELECT PCIe OPTION CARD(s)The standard PCIe card offerings are: Con
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server22CONFIGURING the SERVERApproved Configurations(1) No RAID controller plug-in card If you did not
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER23STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIESCopper twinax cables and SFP
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server24CONFIGURING the SERVERChoose Optional SFP ModulesOptical Cisco SFP+ modules are listed in Table 1
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER25Figure 5 Network Card Connections
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server26CONFIGURING the SERVERSTEP 8 SELECT AC POWER CORD(s)Using Table 11, select the appropriate AC pow
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER27SFS-250V-10A-AR Power Cord, SFS, 250V, 10A, ArgentinaCAB-9K10A-AU Power Cor
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server28CONFIGURING the SERVERCAB-9K10A-IT Power Cord, 250VAC 10A CEI 23-16/VII Plug, ItalyCAB-9K10A-SW P
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER29STEP 9 ORDER POWER SUPPLYThe C22 M3 server accommodates one power supply. A
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerOVERVIEW3 OVERVIEWThe Cisco® UCS C22 M3 Rack Server combines economics and a density-optimized feat
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server30CONFIGURING the SERVERSTEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARMThe reversible cable
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER31STEP 11 ORDER A TRUSTED PLATFORM MODULETrusted Platform Module (TPM) is a c
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server32CONFIGURING the SERVERSTEP 12 ORDER OPTIONAL USB 2.0 DRIVESYou may order one or two optional USB
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER33STEP 13 SELECT OPERATING SYSTEMSeveral operating systems are available from
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server34CONFIGURING the SERVERVMWare ServerVMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Ye
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER35STEP 14 SELECT OPERATING SYSTEM MEDIA KITSelect the optional operating syst
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server36CONFIGURING the SERVERSTEP 15 SELECT OPTIONAL VALUE-ADDED SOFTWAREYou can select from a variety o
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER37STEP 16 SELECT SERVICE and SUPPORT LEVELA variety of service options are av
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server38CONFIGURING the SERVERworld. As a part of this service, Cisco will assist in issues involving thi
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER39Mission Critical Support ServiceThis service delivers personalized technica
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server4DETAILED VIEWSDETAILED VIEWSChassis Front ViewFigure 2 shows the Cisco UCS C22 M3 High-Density SFF
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server40CONFIGURING the SERVERabout Cisco Mission Critical Support Service, please visit Data Center Tech
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerOPTIONAL STEP - ORDER RACK(s)41OPTIONAL STEP - ORDER RACK(s)The optional R42610 rack is available f
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server42OPTIONAL STEP - ORDER PDUOPTIONAL STEP - ORDER PDUAn optional power distribution unit (PDU) is av
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL43SUPPLEMENTAL MATERIALCHASSISAn internal view of the C22 M3 chassis with the
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server44SUPPLEMENTAL MATERIALCPUs and DIMMsPhysical LayoutEach CPU has three DIMM channels: CPU1 has cha
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL45Figure 7 Physical Layout of CPU DIMM Channels and Banks285209A0A1B0B1C0C1D
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server46SUPPLEMENTAL MATERIALMemory Population RulesWhen considering the memory configuration of your ser
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL47Recommended Memory PopulationThis section explains the recommended DIMM popu
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server48SUPPLEMENTAL MATERIALSupported DIMM PopulationsThe supported DIMM populations are listed in Table
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL49Low-Voltage DIMM ConsiderationsThe C22 M3 server can be ordered with low-vol
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerDETAILED VIEWS5Chassis Rear ViewFigure 3 shows the external features of the rear panel.Figure 3 C
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server50SUPPLEMENTAL MATERIALRACKSThe Cisco R42610 rack (see Figure 8) is certified for Cisco UCS install
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL51Figure 8 Cisco R42610 RackFront view - door closed Front view - door open
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server52SUPPLEMENTAL MATERIALPDUsCisco RP Series Power Distribution Units (PDUs) offer power distribution
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL53Motherboard USB PortThe C22 M3 SFF motherboard has one general-purpose USB s
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server54SUPPLEMENTAL MATERIALLED IndicatorsThe server contains LED indicators on the front and rear panel
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL55System Status Off UndefinedOn (green) Server is in normal operating conditio
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server56SUPPLEMENTAL MATERIALRear PanelFigure 12 shows the rear panel LEDs.Figure 12 Front Panel LEDsBl
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL57See Table 28 for the functions of the rear panel LEDs.Table 28 Rear Panel L
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server58TECHNICAL SPECIFICATIONSTECHNICAL SPECIFICATIONSDimensions and WeightPower SpecificationsThe gene
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerTECHNICAL SPECIFICATIONS59The general power specifications for the C22 M3 SFF server 650 W power su
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server6BASE SERVER STANDARD CAPABILITIES and FEATURESBASE SERVER STANDARD CAPABILITIES and FEATURESTab le
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server60TECHNICAL SPECIFICATIONSTemperature nonoperating –40 to 149°F (–40 to 65°C)Humidity (RH) nonopera
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerTECHNICAL SPECIFICATIONS61Compliance RequirementsThe regulatory compliance requirements for C-Serie
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server62TECHNICAL SPECIFICATIONS
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerBASE SERVER STANDARD CAPABILITIES and FEATURES7Video The Emulex Pilot 3 Integrated Baseboard Manage
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server8CONFIGURING the SERVERCONFIGURING the SERVERFollow these steps to configure the Cisco UCS C22 M3 H
Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER9STEP 1 VERIFY SERVER SKUVerify the product ID (PID) of the server as shown i