Cisco UCS C240 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
58
TECHNICAL SPECIFICATIONS
Environmental Specifications
The power specifications for the C240 M3 server are listed in Table 33.
Table 33 UCS C240 M3 Environmental Specifications
Parameter Minimum
Temperature operating 41 to 104° F (5 to 40° C)
derate the maximum temperature by 1°C per every 305 m of
altitude above sea level
Temperature nonoperating –40 to 149°F (–40 to 65°C)
Humidity (RH) operating,
non-condensing
10 to 90%
Altitude operating 0 to 3,000 m (0 to 10,000 ft.)
Altitude nonoperating 0 to 12,192 m (0 to 40,000 ft.)
Sound Power level, Measure
A-weighted per ISO7779 LWAd
(Bels)Operation at 73°F (23°C)
5.8
Sound Pressure level, Measure
A-weighted per ISO7779 LpAm
(dBA)Operation at 73°F (23°C)
43