4-20
Cisco 7304 6-Port Clear Channel E3 Line Card Installation and Configuration
OL-5061-01
Chapter 4 Configuring the 6E3 Line Card
DSU Link Doesn’t Work
DSU Link Doesn’t Work
Symptom
The link between the 6E3 line card and digitial link DSU (DL3100E) doesn't work when subrates have
been configured. Pings don't go through.
Note This is an intermittent problem that occurs with the DL3100E DSU. Other supported external CSU and
DSU products are not affected.
Conditions
This symptom is observed after you have reloaded a Cisco 7304, (when a 6-port E3 line card is connected
to an external digital link DSU) and when the interface has the
dsu bandwidth command enabled.
Workaround
Enter the shutdown command followed by the no shutdown command on the affected interface.
Router#conf t
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#int ser 5/0
Router(config-if)#shut
Router(config-if)#no shut
*Oct 20 21:39:34.331: %LINK-5-CHANGED: Interface Serial5/0, changed state to
administratively down
Router(config-if)#
*Oct 20 21:39:34.331: %WS_ALARM-6-INFO: ASSERT INFO Se5/0 Physical Port Administrative
State Down
*Oct 20 21:39:35.331: %LINEPROTO-5-UPDOWN: Line protocol on Interface Serial5/0, changed
state to down
*Oct 20 21:39:37.263: %LINK-3-UPDOWN: Interface Serial5/0, changed state to down
*Oct 20 21:39:37.263: %WS_ALARM-6-INFO: CLEAR INFO Se5/0 Physical Port Administrative
State Down
*Oct 20 21:39:37.263: %WS_ALARM-6-INFO: ASSERT MAJOR Se5/0 Physical Port Link Down
Router(config-if)#
Router(config-if)#
*Oct 20 21:39:41.895: %LINK-3-UPDOWN: Interface Serial5/0, changed state to up
*Oct 20 21:39:41.895: %WS_ALARM-6-INFO: CLEAR MAJOR Se5/0 Physical Port Link Down
*Oct 20 21:39:42.895: %LINEPROTO-5-UPDOWN: Line protocol on Interface Serial5/0, changed
state to up
Router(config-if)#end
Router#