Vista de página 270
Split and Non-Split Mode for Power Supply and Fan Tray
4025561 Rev
A
247
Split and Non-Split Mode for Power Supply and
Fan Tray
This section explains the difference between Split and Non-Split mode reporting of
Prisma II EMS power supply and fan tray module parameters.
Overview
All Prisma II EMS system releases associate fan tray and power supply parameters
with chassis slot numbers. In System Release 1.00, all fan tray and power supply
parameters are associated with the slot number of the installed power supply
module or modules. Consequently, if Power Supply 1 and Power Supply 3 are both
installed, any alarm condition affecting the fan tray or either power supply module
is reported twice: once for chassis slot 1, and again for chassis slot 3.
To prevent duplicate alarms with both power supplies installed, this method of
reporting module parameters was changed beginning with System Release 1.01. The
fan tray, which previously had no physical chassis slot number assigned, was
defined as occupying chassis slot 0. This change allowed each fan tray or power
supply parameter to be associated with one and only one chassis slot number. As a
result, a System Release 1.01 or later chassis associates fan tray parameters with
chassis slot 0, power supply 1 parameters with chassis slot 1, and power supply 3
parameters with chassis slot 3.
The association of each fan tray and power supply parameter with only one chassis
slot number in System Release 1.01 is termed Split mode. Split mode is achieved
only when both the controlling ICIM2 and the fan tray in a chassis have System
Release 1.01 or later firmware. If either the controlling ICIM2 or the fan tray has
System Release 1.00 firmware, the chassis reports fan tray and power supply
parameters according to System Release 1.00 behavior, now termed Non-Split mode.
This scheme maintains backward compatibility for any chassis in which the fan tray
and controlling ICIM2 have different System Release firmware.
The following table summarizes the mode of reporting for each possible
combination of ICIM2 and fan tray firmware.
Fan Tray Firmware ICIM2 Rel 1.00 ICIM2 Rel 1.01 or later
System Release 1.00 Non-Split Non-Split
System Release 1.01 or later Non-Split Split
Note:
The difference between the Non-Split behavior of Release 1.00 and the Split
behavior of later system releases is apparent in all product interfaces: the ICIM2
front panel, the CLI, and SNMP management information bases (MIBs) and
traps.