74 4025561
Rev
set control
Syntax
set control controlName controlValue
Description
The set control command is followed by two additional arguments: controlName
identifies the control parameter, and controlValue specifies the value to be assigned.
Important: To avoid possible system disruption, broadcast set commands are not
supported. This means that the set control command can only be applied to one
module (chassis and slot number) at a time. If a specific chassis and slot number are
not specified in advance, the CLI interpreter will disallow the command. In addition,
the name of the control to be changed must be explicit; no wildcard characters are
permitted.
Control Types
Control parameters are classified as type F (floating-point) or type S (state) to
characterize the types of variables they control. In general:
Type F controls are numeric values that can vary between maximum and
minimum thresholds. The adjustment increments are set by separate hysteresis
values for each control.
Type S controls are state variables that have a limited range of discrete values
such as On or Off, Master or Slave, Auto or Manual, and so on. The set of
possible values is defined as appropriate for each control.
Parameters
The possible values for controlName and controlValue depend on the application
module in question. The following tables identify the controls for each application
module along with their types and possible values.
Note: When selecting control parameters for this command, one or more wildcard
characters (*) may be used to specify a range of matching responses.
Transmitter (devtype: 1033)
Control Description Type Possible Values
Enable Enables or disables the laser. S On (1), Off (0)