Cisco GoQAM Informações Técnicas Página 77

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 308
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 76
info alarm
4025561 Rev
A
53
Detail parameter Description
Type Alarm type (types 1, 2, and 7 are adjustable).
Value Alarm state.
Access Rights Required
Read, ReadWrite, or Admin
Example
The following sample dialog illustrates the use of the info alarm command to view
the thresholds of a post-amplifier output power alarm. Note that these thresholds
are relative to the nominal alarm value.
02/05 MODULE> info alarm outpwra majorhigh minorhigh minorlow majorlow
hysteresis nominal
MODID NAME MAJORHIGH MINORHIGH MINORLOW MAJORLOW HYSTERESIS NOMINAL
02/05 OutPwrA 1 0.7 -0.7 -1 0.1 17.7
SUCCESS!
02/05 MODULE>
Related Commands
info control
info module
info monitor
show alarmstate