Cisco 15310-MA Guia de Resolução de Problemas Página 119

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 118
1-83
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 1 General Troubleshooting
Circuits and Timing
1.11.4 Circuit Creation Error with VT1.5 Circuit
Symptom You might receive an “Error while finishing circuit creation. Unable to provision circuit.
Unable to create connection object at node-name” message when trying to create a VT1.5 circuit in CTC.
Table 1-25 describes the potential causes of the symptom and the solutions.
1.11.5 OC-3 and DCC Limitations
Symptom There are limitations to OC-3 and DCC usage.
Table 1-26 describes the potential cause of the symptom and the solution.
1.11.6 ONS 15310-CL or ONS 15310-MA Switches Timing Reference
Symptom Timing references switch when one or more problems occur.
Table 1-27 describes the potential causes of the symptom and the solutions.
Table 1-25 Circuit Creation Error with VT1.5 Circuit
Possible Problem Solution
You might have run out
of bandwidth on the VT
cross-connect matrix at
the node indicated in the
error message.
The ONS 15310-CL matrix has a maximum capacity of 336 bidirectional
VT1.5 cross-connects. The ONS 15310-MA capacity is 1,064.
Table 1-26 OC-3 and DCC Limitations
Possible Problem Solution
OC-3 and DCC have
limitations for the
system.
For an explanation of OC-3 and DCC limitations, refer to the “DCC
Tunnels” section in the Cisco ONS 15310-CL and Cisco ONS 15310-MA
Procedure Guide.
Vista de página 118
1 2 ... 114 115 116 117 118 119 120 121 122 123 124 ... 379 380

Comentários a estes Manuais

Sem comentários