2-126
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
Warning
Before working on equipment that is connected to power lines, remove jewelry (including rings,
necklaces, and watches). Metal objects will heat up when connected to power and ground and can
cause serious burns or weld the metal object to the terminals.
Statement 43
Clear the PWR-FAIL-B Alarm
Step 1 Complete the “Clear the PWR-FAIL-A Alarm” procedure on page 2-125.
Step 2 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447).
2.7.197 RAI
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: DS1, DS3
The Remote Alarm Indication (RAI) condition signifies an end-to-end failure. The error condition is sent
from one end of the SONET path to the other. RAI on a DS-3 port indicates that the far-end node is
receiving a DS-3 AIS.
Clear the RAI Condition
Step 1 Complete the “Clear the AIS Condition” procedure on page 2-21.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.198 RFI-L
Default Severity: Not Reported (NR), Non-Service-Affecting (NSA)
SONET Logical Objects: EC1, OCN
A Remote Fault Indication (RFI) Line condition occurs when the ONS 15310-CL or ONS 15310-MA
detects an RFI in OC-3 or OC-12 port SONET overhead because of a fault in another node. Resolving
the fault in the adjoining node clears the RFI-L condition in the reporting node. RFI-L indicates that the
condition is occurring at the line level.
Clear the RFI-L Condition
Step 1 Log into the node at the far-end of the reporting ONS 15310-CL or ONS 15310-MA.
Step 2 Identify and clear any alarms, particularly the “LOS (OCN)” alarm on page 2-106.