2-10
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Logical Objects
2.3 Alarm Logical Objects
The CTC alarm profile list organizes all alarms and conditions according to the logical objects they are
raised against. These logical objects represent physical objects such as cards, logical objects such as
circuits, or transport and signal monitoring entities such as the SONET overhead bits. One alarm can
appear in multiple entries. It can be raised against multiple objects. For example, the loss of signal (LOS)
alarm can be raised against the optical signal (OC-N) or the optical transport layer overhead (OTN) as
well as other objects. Therefore, both OCN: LOS and OTN: LOS appear in the list (as well as the other
objects).
Alarm profile list objects are defined in Table 2-7.
Note Alarm logical object names can appear as abbreviated versions of standard terms used in the system and
the documentation. For example, the “OCN” logical object refers to the OC-N signal. Logical object
names or industry-standard terms are used within the entries as appropriate.
FE-FRCDWKSWPR-SPAN (OCN) OOU-TPT (VT-TERM) TX-AIS (DS3)
FE-IDLE (DS3) OPEN-SLOT (EQPT) TX-IDLE (DS1)
FE-LOCKOUTOFPR-SPAN (OCN) PDI-P (STSMON) TX-LOF (DS1)
FE-LOF (DS3) PDI-P (STSTRM) TX-RAI (DS1)
FE-LOS (DS3) PLM-P (STSMON) TX-RAI (DS3)
FE-MANWKSWBK-SPAN (OCN) PLM-P (STSTRM) UNEQ-P (STSMON)
FE-MANWKSWPR-SPAN (OCN) PLM-V (VT-MON) UNEQ-P (STSTRM)
FEPRLF (OCN) PLM-V (VT-TERM) UNEQ-V (VT-MON)
FORCED-REQ (STSMON) PORT-MISMATCH (CEMR) UNEQ-V (VT-TERM)
FORCED-REQ (VT-MON) PRC-DUPID (OCN) UNQUAL-PPM (PPM)
FORCED-REQ-SPAN (OCN) PROTNA (EQPT) VCG-DEG (VCG)
FP-LINK-LOSS (EQPT) PROV-MISMATCH (PPM) VCG-DOWN (VCG)
FRCDSWTOINT (NE-SREF) PWR-FAIL-A (EQPT) WKSWPR (EQPT)
FRCDSWTOPRI (EXT-SREF) PWR-FAIL-B (EQPT) WKSWPR (OCN)
FRCDSWTOPRI (NE-SREF) RAI (DS1) WKSWPR (STSMON)
FRCDSWTOSEC (EXT-SREF) RAI (DS3) WKSWPR (VT-MON)
FRCDSWTOSEC (NE-SREF) RFI-L (EC1) WTR (EQPT)
FRCDSWTOTHIRD (EXT-SREF) RFI-L (OCN) WTR (OCN)
FRCDSWTOTHIRD (NE-SREF) RFI-P (STSMON) WTR (STSMON)
FRNGSYNC (NE-SREF) RFI-P (STSTRM) WTR (VT-MON)
FSTSYNC (NE-SREF) RFI-V (VT-MON) —
FULLPASSTHR-BI (OCN) RFI-V (VT-TERM) —
Table 2-6 ONS 15310-CL and ONS 15310-MA Alarm and Condition Alphabetical List (continued)
Comentários a estes Manuais