Cisco 15310-MA Guia de Resolução de Problemas Página 96

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 95
1-60
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 1 General Troubleshooting
Verify Wiring from the ONS 15310-MA Shelf and DSX Wiring Panel
1.7.3.3 Provision the Handheld Receiver and Perform Automatic Mode Testing
Step 1 Turn on the handheld receiver and observe the display. Adjust the settings (DS l/DS3 or OK PROMPT)
as needed:
a. To change from DS-1 to DS-3 or from DS-3 to DS-1, press the MENU key once, use the DISPLAY
key to change the selection, and the ENTER/ACCEPT key to save the selection.
b. To change the OK PROMPT setting, press the MENU key four times, use the DISPLAY key to
change the selection, and the ENTER/ACCEPT key to save the selection
Step 2 To set the audible tone ON, press the MENU key five times, use the DISPLAY key to change the
selection, and the ENTER/ACCEPT key to save the selection
Step 3 Insert an appropriate patch cord into the handheld receiver.
Step 4 At this point, the handheld receiver is still in the manual mode. Press the BEGIN TEST key to enter the
automatic mode.
Note Pushing the BEGIN TEST key when testing DS-1 wiring starts the automatic test mode at DS-1 port 1
and continues for all 84 ports. To start testing at the DS-1 ports of the second connector pair, ports 29 to
56, push the BEGIN TEST key a second time, and the handheld receiver skips ahead to prompt for the
DS I port 29. Pushing BEGIN TEST a third time advances the handheld receiver to start testing at the
last DS-1 group, DS 1 port 57.
At any time, you may press EXIT TEST, which terminates the automatic test mode, stores the results
thus far, and returns the handheld receiver to the manual mode. This is a convenient feature that, along
with the skip ahead feature, allows automatic testing and result storage for a portion of the shelf's
connector wiring.
Step 5 Insert the other end of the patch cord into the requested port shown on the display screen.
Step 6 Wait a few seconds for the handheld receiver to detect the signal. For a good measurement in full
automatic mode, the handheld receiver displays OK, beeps, and then shows the next port to test.
Step 7 If there is an error, or if the OK PROMPT mode is active, press the ENTER/ACCEPT key to store the
result.
Step 8 Move the patch cord to the next port to be tested, as shown in the GOTO message on the display.
Step 9 Repeat Step 5 through Step 8 until all ports are tested.
Note Press the EXIT TEST key to abort the testing at any time. The results to that point are stored in memory,
and the handheld receiver reverts to manual mode.
1.7.3.4 View Automatic Mode Test Results During the Test
During the automatic test, there are many test conditions and messages that can appear. A few examples
are given in Table 1-2 for DS-1 signal ports. Similar messages appear for the DS-3 ports.
Vista de página 95
1 2 ... 91 92 93 94 95 96 97 98 99 100 101 ... 379 380

Comentários a estes Manuais