2-69
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
Step 4 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.87 FE-LOS
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: DS3
The Far End LOS condition occurs in C-bit line type mode when a far-end node reports the “LOS (DS3)”
alarm on page 2-102.
Clear the FE-LOS Condition
Step 1 To troubleshoot the FE condition, determine which node and port link directly to the card or port
reporting the FE condition.
Step 2 Log into the node that links directly to the port reporting the FE condition.
Step 3 Complete the “Clear the LOS (DS1) Alarm” procedure on page 2-101.
Step 4 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.88 FE-MANWKSWBK-SPAN
The FE-MANWKSWBK-SPAN condition is not used in the ONS 15310 platforms in this release. It is
reserved for development.
2.7.89 FE-MANWKSWPR-SPAN
The FE-MANWKSWPR-SPAN condition is not used in the ONS 15310 platforms in this release. It is
reserved for development.
2.7.90 FEPRLF
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: OCN
The Far End Protection Line Failure alarm occurs when an APS channel “SF-L” condition on page 2-134
occurs on the protect port coming into the node.
Note The FEPRLF alarm occurs when bidirectional protection is used on optical ports in a 1+1 protection
group configuration.