Cisco 15310-MA Guia de Resolução de Problemas Página 253

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 252
2-123
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
Warning
Invisible laser radiation could be emitted from the end of the unterminated fiber cable or connector.
Do not stare into the beam directly with optical instruments. Viewing the laser output with certain
optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of
100 mm could pose an eye hazard.
Statement 1056
Warning
Use of controls, adjustments, or performing procedures other than those specified could result in
hazardous radiation exposure.
Statement 1057
Clear the PLM-P Alarm
Step 1 Complete the “Clear the PDI-P Condition” procedure on page 2-122.
Step 2 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447) in order to report a Service-Affecting (SA)
problem.
2.7.190 PLM-V
Default Severity: Major (MJ), Service-Affecting (SA)
SONET Logical Object: VT-TERM, VT-MON
A Payload Label Mismatch VT Layer alarm raises when the content of the V5 byte in the SONET
overhead is inconsistent or invalid. PLM-V occurs when ONS 15310-CLs or ONS 15310-MAs
interoperate with equipment that performs bit-synchronous mapping for DS-1 signal. The node uses
asynchronous mapping.
Clear the PLM-V Alarm
Step 1 Verify that your signal source matches the signal allowed by the traffic card. For example, the alarm will
occur if your signal source uses VT6 or VT9 mapping, because this is not supported by a
15310-CL-CTX, DS1-28/DS3-EC1-3, or DS1-84/DS3-EC1-3 card.
Step 2 If the signal source matches the card, verify that the SONET VT path originator is sending the correct
VT label value. You can find the SONET VT path originator using circuit provisioning steps.
Step 3 If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447) in order to report a Service-Affecting (SA)
problem.
2.7.191 PORT-MISMATCH
The PORT-MISMATCH alarm is not used in the ONS 15310 platforms in this release. It is reserved for