2-133
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
2.7.209 SD-P
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: STSMON, STSTRM
An SD Path condition applies to the path (STS) layer of the SONET overhead. A path or ST-level SD
alarm travels on the B3 byte of the SONET overhead.
For UPSR-protected circuits, the BER threshold is user-provisionable and has a range for SD from
1E–9 dBm to 1E–5 dBm. For 1+1 and unprotected circuits, the BER threshold value is not
user-provisionable and the error rate is hard-coded to 1E–6 dBm. An SD-P condition causes a switch
from the working port to the protect port at the path (STS) level.
The BER increase that causes the condition is sometimes caused by a physical fiber problem such as a
poor fiber connection, a bend in the fiber that exceeds the permitted bend radius, or a bad fiber splice.
SD causes the port to switch from working to protect. The SD condition clears when the BER level falls
to one-tenth of the threshold level that triggered it.
Clear the SD-P Condition
Step 1 Complete the “Clear the SD-L Condition” procedure on page 2-132.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.210 SD-V
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: VT-MON, VT-TERM
An SD-V condition is similar to the “SD” condition on page 2-130, but it applies to the VT layer of the
SONET overhead.
For UPSR protected circuits, the BER threshold is user-provisionable and has a range for SD from
1E–9 dBm to 1E–5 dBm. An SD-V condition does not cause a switch from the working port to the
protect port at the path (STS) level.
The BER increase that causes the alarm is sometimes caused by a physical fiber problem such as a poor
fiber connection, a bend in the fiber that exceeds the permitted bend radius, or a bad fiber splice.
SD causes the port to switch from working to protect. The SD condition clears when the BER level falls
to one-tenth of the threshold level that triggered it.
Clear the SD-V Condition
Step 1 Complete the “Clear the SD (DS1, DS3) Condition” procedure on page 2-131.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).